1 thought on “hong kong wholesale jewelry supplies Starccm installation cannot find a Java virtual machine”
Stanley
wholesale jewelry houston You can see if you have installed Java. First, check whether you have the Java version that matches the current NX version. If not, please install it. You can view it in the control panel program. If there is a updated version or the older version, you can uninstall and install it first. Note that Java has 32 -bit and 64 -bit points. When installing, do not modify its path, just install it directly by default. Secondly, this problem can be confirmed that Java does not match the normal matching of NX software. Most computers generally only need to install the matching Java version, but there are a small part of the version that needs to be added with an additional environment variable. The first method: There are generally two environment variables, and you can add a test one by one. Variable name: UGII_JAVA_HOME Value Value: Your current Java program is located, such as mine: c: javajre1.8.0_172 Variable name: UGII_JVM_Library_dir Value, as above. After adding this, re -open the NX software test. If it is still not good, please press the following methods. This to modify the ugii_env file on the warning picture prompt to test, and the modification of this file is actually the same as adding an environment variable. Different NX versions may modify the difference in files, and they are generally the UGII_ENV.DAT or UGII_ENV_UG.DAT file in the ugii directory. The path of this file is (this is my path): C: Siemensnx12.0ugiiugii_env.dat or: c: siemensnx12.0ugiiugii_env_ug.dat, plus your environmental variables and variable values, for example: ugii_java_home = c = c : Javajre1.8.0_172 Generally recommend adding system environment variables directly, saving the files to make confusion.
wholesale jewelry houston You can see if you have installed Java.
First, check whether you have the Java version that matches the current NX version. If not, please install it. You can view it in the control panel program. If there is a updated version or the older version, you can uninstall and install it first. Note that Java has 32 -bit and 64 -bit points. When installing, do not modify its path, just install it directly by default. Secondly, this problem can be confirmed that Java does not match the normal matching of NX software. Most computers generally only need to install the matching Java version, but there are a small part of the version that needs to be added with an additional environment variable. The first method: There are generally two environment variables, and you can add a test one by one. Variable name: UGII_JAVA_HOME Value Value: Your current Java program is located, such as mine: c: javajre1.8.0_172 Variable name: UGII_JVM_Library_dir Value, as above. After adding this, re -open the NX software test. If it is still not good, please press the following methods.
This to modify the ugii_env file on the warning picture prompt to test, and the modification of this file is actually the same as adding an environment variable. Different NX versions may modify the difference in files, and they are generally the UGII_ENV.DAT or UGII_ENV_UG.DAT file in the ugii directory. The path of this file is (this is my path): C: Siemensnx12.0ugiiugii_env.dat or: c: siemensnx12.0ugiiugii_env_ug.dat, plus your environmental variables and variable values, for example: ugii_java_home = c = c : Javajre1.8.0_172 Generally recommend adding system environment variables directly, saving the files to make confusion.